Header

power products & solutions

gray triangle
Power Products & Solutions, Inc.
Assuring Electrical Performance
Ralph Patterson
Phone: 704-573-0420
Fax: 704-573-3693
Cell: 704-351-2723
Email: ralph.patterson@powerproducts.biz
Raymond Pesaturo
Phone: 704-573-0420
Fax: 704-573-3693
Cell: 980-722-8155
Email: raymond.pesaturo@powerproducts.biz
MV Cable Services Detail
2010 Power Products & Solutions, Inc.  All Rights Reserved
 

One of Power Products & Solutions fastest growing services is our Medium Voltage Cable Termination and Testing service.  We are one of the leading medium voltage cable terminator and testing companies in the North and South Carolina area with a total termination count of over a thousand medium voltage terminations for the first six months of 2010.  With our technicians installing so many medium voltage terminations, you can rest assured that their termination and testing skills are at peak performance.

With this sector of our business showing steady growth, we are always looking at ways we can provide our customers more services that will meet their needs concerning maintenance of their medium voltage cables.  We have found that a large percentage of our customers are concerned about the longevity of their medium voltage cables feeding their facilities.  This concern has prompted many of our customer’s maintenance and plant managers to include visual and mechanical inspections and non-destructive testing of their MV cables on a more consistent basis.  So we took note of our customers concerns and invested in a Tan Delta cable test set to meet their IEEE medium voltage cable testing specifications and requirements.

We have performed Tan Delta testing for some of our customers who have vintage medium voltage cables and the results have been quite impressive.  Our customers have already seen benefits to using this latest progression in the technology of cable testing by finding problems in cable terminations and splices.  By performing Tan Delta testing on our customers medium voltage cables, we gain the ability to gather and record test data, and we can use this data to determine if the cables have developed any signs of deterioration from previous testing.  There are also advantages in performing Tan Delta testing on new medium voltage cable installations.  By performing Tan Delta testing when the cables are placed into service and re-testing on a consistent three to five year maintenance cycle, we can determine the life expectance of the conductors and locate any problems before they play havoc on the electrical system.  If you wish to have further information on Tan Delta testing or any other medium cable testing services that we offer, please contact us.

Medium_Voltage_Terms
Load Side Terminations in an Outdoor Load-Break Switch
Cable terminations in GE gear at UVA in Charlottesville, VA
15KV Cable Terminations at NCCU in Durham, NC
Medium Voltage Cable Terminations and Testing
Landing_MV_Terms
Install_MV_Terms
NETA Certified

Air Circuit Breaker Articles of Interest


                What is Partial Discharge Resistance?
               
                What is Tan Delta Cable Testing?

                Water Trees are Significant

                Insulation Resistance / Cable Testing - How & Why?